Product

LASER HUNTER

DivisionDetail
DisplayLCD graphic display 128 x 64 Pixel, illuminable
Display of measured value, maximum value and bar graph
Power supplyLithium-Ionen 7,2 V 6.700 mAh
ChargingCharging cradle supplied by 12 Volt or 230 Volt
approx. 5 hours
Operating time> 10 hours (without backlight)
Data Store> 2,000,000 Measured value (depending on the measurement period)
Protection categoryIP 52
Dimensions230 x 115 x 85 mm without couplings
Weightca. 2.1kg
Measurement principleLaser
Measuring range0 to 1.000 ppm CH4, Resolution: up to 0,5 ppm
0,1 to 2,2 Vol.% CH4, Resolution: 0,01 Vol.%
0 to 1.000 ppm C2H6, Resolution: 5 ppm
Pumping capacity> 80l/h, > 300mbar
Laser HUNTER is an equipment for measuring ultra-low concentrations accurately and for systematic inspection. No erroneous measurements due to humidity or other gases due to innovative laser technology. The latest version uses a sensor to quickly and simply distinguish between natural gas or biogas (ethane detection) to determine the exact location, which is time-consuming and costly. If desired, the equipment can be equipped with additional sensor technology for additional applications in the pipeline inspection process. So you have it all in this one piece of equipment.